Lateral Torsional Buckling of Timber Beams

Lateral torsional buckling describes the behaviour of a beam that is prone to lateral/horizontal buckling in the compression zone due to bending moments.
In this article, you’ll learn how to verify timber beams according to Eurocode.
Now, let’s get into it.
What Is Lateral Torsional Buckling?
Lateral torsional buckling is a phenomenon that can happen to steel, precast concrete and timber beams.
It describes the behaviour of a beam that is prone to lateral/horizontal buckling in the compression zone due to bending moments.
At the same time, the tension zone of the cross-section tends to remain almost undeformed. This results in a rotational and lateral deformation of the beam like in the following picture.

The support conditions influence the beam’s ability to buckle laterally.
- Fixed supports provide a good torsional restraint, which leads to a greater lateral torsional buckling resistance.
- Pinned supports lead to a smaller lateral torsional buckling resistance.
- Lateral torsional movement restraints in the span of the beam also lead to a greater lateral torsional buckling resistance. Examples are beams that run transverse to the beams with a stiff connection.
Now, let’s get into the nerdy calculations..
The 4 Steps To Verify Timber Beams For Lateral Torsional Buckling
We use the secondary beam of the canopy structure below to show the calculation steps.
Also let’s assume that the beam is not held horizontally by some sheeting like trapezoidal sheeting or OSB boards.

Step #1: Define the material properties of the timber element
We first define the material properties of the timber beam. In this tutorial, we’ll use C24 as the timber material.
For small structures like this which aren’t exposed to big loads, C24 is enough.
We summarized all timber materials as a blogpost (click here).
Here are the strength and stiffness properties of C24.
Strength values in MPa | C24 | |
---|---|---|
Bending strength | fm.g.k | 24 |
Tensile strength parallel to grain | ft.0.g.k | 14 |
Tensile strength perpendicular to grain | ft.90.g.k | 0.4 |
Compressive strength parallel to grain | fc.0.g.k | 21 |
Compressive strength perpendicular to grain | fc.90.g.k | 2.5 |
Shear strength | fv.g.k | 4.0 |
Modulus of elasticity | E0.g.mean | 11000 |
E0.g.05 | 7400 | |
Shear modulus | Gg.mean | 690 |
Density in kg/m3 | ||
ρg.k | 350 | |
ρg.mean | 420 |
The partial safety factor is found in EN 1995-1-1 Table 2.3 as:
γM = 1.3
The beam is classified according to EN 1995-1-1 2.3.1.3 as service class 2 (assumption in this tutorial).
Then we’ll verify the timber beam for a design load of load duration class short-term (EN 1995-1-1 Table 2.1) which leads to a modification factor (EN 1995-1-1 Table 3.1) of:
kmod = 0.9
Step #2: Define the geometrical properties of the timber beam
The beam has the following cross-sectional properties:
- Cross-sectional height h=20cm
- Cross-sectional width w=12cm
- Moment of inertia strong axis Iy = (w ⋅ h3)/12 = 8 ⋅ 107 mm4
- Moment of inertia weak axis Ix = (h ⋅ w3)/12 = 2.88 ⋅ 107 mm4
- Torsional moment of inertia Itor = 1/3 ⋅ h ⋅ w3 ⋅ (1 – 0.63 ⋅ w/h + 0.052 ⋅ w5/h5) = 7.2 ⋅ 107 mm4
- Length (=span) s=5m
Step #3: Calculate the loads and internal forces acting in the timber element
First, we need to calculate the characteristic loads that act on the roof area of the canopy. The area loads are applied to the roof panels (could be OSB boards or trapezoidal steel sheeting).
These panels then transfer the loads to the secondary beams, which we verify for lateral torsional buckling in this tutorial. This video explains transferring vertical loads in detail (click → here ←).

We won’t show how to calculate the loads and how to do the load transfer in this article, as each calculation of the individual load is an article for itself.
But that’s exactly what I teach in Module #2: Structural Design of a Residential Timber Roof.
In this post, we’ll design the secondary timber beam for the following design line load.
Design line load:
pd = 4.0 kN/m

From design load, we’ll calculate the design bending moment:
Md = pd ⋅ s2/8 = 12.5 kNm
The design normal force is 0 kN:
Nd = 0 kN
Step #4: Verify the timber beam for lateral torsional buckling
Bending stress (short term load) | σm.d = Md/Iy ⋅ h/2 = 15.6 MPa |
Compression stress (short term load): | σc.d = Nd/(w⋅h) = 0 MPa |
Design bending resistance | fm.d = kmod ⋅ fm.k/γM = 17.3 MPa |
Design compression resistance: | fc.0.d = kmod ⋅ fc.0.k/γM = 15.1 MPa |
Effective length of the beam according to EN 1995-1-1 Table 6.1 | lef = 0.9 ⋅ s + 2 ⋅ h = 4.9m |
Critical bending stress (EN 1995-1-1 (6.31)) | $\sigma_{m.crit} = \pi \cdot \frac{\sqrt{E_{0.g.05} \cdot I_z \cdot G_{g.05} \cdot I_{tor}}}{l_{ef} \cdot W_y} = 67.4 MPa$ |
Relative slenderness (EN1995-1-1 (6.30)) | λrel.m = √(fm.k/σm.crit) = 0.60 |
Factor for reduced bending strength due to lateral torsional buckling (EN1995-1-1 (6.34)) | λrel.m < 0.75 → kcrit = 1 |
Now we only need the following formulas if there is also a normal force acting in the beam. In our case the normal force is 0 kN. But I’ll still include the formulas to show you hwo to do it.
Buckling length out-of-plane | lz = 5m |
Radius of inertia (weak axis) | iz = √(Iz/w ⋅ h) = 0.035 |
Slenderness ratio | λz = lz/iz = 144.34 |
Relative slenderness ratio (EN 1995-1-1 (6.22)) | λrel.z = λz/π ⋅ √(fc.0.k/E0.g.05) = 2.45 |
Factor for members within the straightness limits (EN 1995-1-1 (6.29)) | βc = 0.2 |
Instability factor (EN1995-1-1 (6.28)) | kz = 0.5 ⋅ (1 + βc ⋅ (λrel.z – 0.3) + λrel.z2) = 3.7 |
Buckling reduction coefficient (EN1995-1-1 (6.26)) | kc.z = 1/(kz + √(kz2 – λrel.z2)) = 0.15 |
Utilization (EN1995-1-1 (6.35)) | η = (σm.d/(kcrit ⋅ fm.d))2 + σc.d/(kc.z ⋅ fc.0.d) = 0.82 |
Utilization (EN1995-1-1 (6.35)):
η = (σm.d/(kcrit ⋅ fm.d))2 + σc.d/(kc.z ⋅ fc.0.d) = 0.82
Final words
Lateral torsional buckling is quite a complex phenomenon in structural engineering, and it takes a lot of time to understand. But it can happen to most beams.
Therefore, it’s important to understand it.
If you don’t want to miss any new structural design tutorials, then subscribe to our free weekly newsletter.
Or subscribe to my YouTube channel for regular updates.
Let’s design better structures together,
Laurin.

Laurin Ernst